Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
Clinics in Orthopedic Surgery ; : 203-210, 2023.
Article in English | WPRIM | ID: wpr-966718

ABSTRACT

Background@#Subchondral fatigue fracture of the femoral head (SFFFH) is a rare disease, and its disease entity is established in recent decades. Although there are a few studies on SFFFH, most of them are case series involving around 10 cases, and the clinical course of SFFFH is still not well known. This study analyzed the factors affecting the clinical course of SFFFH. @*Methods@#Patients who visited our institution from October 2000 to January 2019 were retrospectively evaluated. Of eligible cases, 89 hips (80 patients) were diagnosed with SFFFH and non-surgical treatment outcomes were analyzed. Radiographs and medical charts were reviewed for following factors: the degree of femoral head collapse, the interval between the onset of hip pain and the first hospital visit, hip dysplasia, osteoarthritic changes, sex, and age. @*Results@#Hip pain decreased in 82 cases (92.1%) through non-surgical treatment, and 7 cases (7.9%) underwent surgery. Patients with good results of non-surgical treatment had improvement 2.9 months on average after the treatment. All cases without a collapsed femoral head (55 cases) had hip pain alleviation through non-surgical treatment. Cases with femoral head collapse of 4 mm or less and non-surgical treatment within 6 months from the onset of hip pain (22 cases) all had hip pain alleviation. Among 8 cases with femoral head collapse of 4 mm or less and non-surgical treatment after 6 months or more from the onset of hip pain, 3 underwent surgery and 1 had persistent hip pain. Those with femoral head collapse of over 4 mm (3 cases) all underwent surgery. The osteoarthritic changes, dysplastic hip, sex, and age were not statistically related to the success of non-surgical treatment. @*Conclusions@#The success of non-surgical treatment for SFFFH can be affected by the degree of femoral head collapse and the timing of non-surgical treatment.

2.
Clinics in Orthopedic Surgery ; : 211-218, 2023.
Article in English | WPRIM | ID: wpr-966715

ABSTRACT

Background@#Early firm fixation of the femoral implant is crucial in total hip arthroplasty (THA) with unstable metaphysis or a large degree of femoral bone loss. This study aimed to evaluate the outcomes of THA using a novel cementless modular, fluted, tapered stem in such cases. @*Methods@#From 2015 to 2020, 105 hips (101 patients) had surgery performed by two surgeons at two tertiary hospitals using a cementless modular, fluted, tapered stem for periprosthetic fractures, massive bone loss, prosthetic joint infection sequelae, or tumorous condition. Clinical outcomes, radiographic results, and survivorship of the implant were evaluated. @*Results@#The average follow-up period was 2.8 years (range, 1–6.2 years). The Koval grade was 2.7 ± 1.7 preoperatively and maintained at 1.2 ± 0.8 at the latest follow-up. The plain radiograph showed bone ingrowth fixation in 89 hips (84.8%). The average stem subsidence at postoperative 1 year was 1.6 ± 3.2 mm (range, 0–11.0 mm). Five reoperations (4.8%) were needed, including 1 for acute periprosthetic fracture, 1 for recurrent dislocation, and 3 for chronic periprosthetic joint infection. Kaplan-Meier survivorship with reoperation for any reason as the endpoint was 94.1%. @*Conclusions@#The early- to mid-term results of THA with the novel cementless modular, fluted, tapered THA stem system were satisfactory clinically and radiologically. The shortcomings inherent to its modularity were not identified. This modular femoral system may provide adequate fixation and be a practical option in the setting of complicated THA.

3.
Clinics in Orthopedic Surgery ; : 367-372, 2023.
Article in English | WPRIM | ID: wpr-976752

ABSTRACT

Background@#Studies have reported that osteonecrosis of the femoral head (ONFH) is more prevalent in patients with human immunodeficiency virus (HIV). Total hip arthroplasty (THA) is considered reasonable management of ONFH. However, only scarce data exist on the outcomes of THA for HIV-infected patients in South Korea. The purpose of this study was to evaluate the midterm results of HIV-positive patients who underwent THA for ONFH. @*Methods@#We performed a retrospective review of HIV-infected patients with ONFH who underwent THA in our institution from 2005 to 2021. Twenty-two hips in 15 patients underwent THAs with cementless implants. The clinical and radiographic evaluation was performed at each follow-up, and any complication was recorded. @*Results@#The mean follow-up period was 5.2 years (range, 1.0–16.0 years). The mean age of the HIV infected patients with osteonecrosis at the time of surgery was 44.7 ± 11.6 years. ONFH occurred 9.8 ± 3.7 years after the initial diagnosis of HIV infection.The average modified Harris hip score improved from 58.3 ± 14.8 to 95.2 ± 11.3 at the latest follow-up. Surgical complications such as infection, nerve injury, or dislocation were not present. The radiographic evidence of stable fixation by bone ingrowth without migration was seen in all implants. @*Conclusions@#Our data suggest that THA is a safe and valid option of treatment for ONFH in well-controlled HIV-infected patients in Korea. Further large-scale nationwide studies are warranted.

4.
The Journal of the Korean Orthopaedic Association ; : 27-34, 2023.
Article in English | WPRIM | ID: wpr-968970

ABSTRACT

Purpose@#This study examined the clinical and radiological results of cementless hip arthroplasty using a long double-tapered rectangular stem in cases with osteoporotic proximal femoral fractures or in reoperation cases. @*Materials and Methods@#This was a retrospective study on patients treated with a Benfix ® stem (Corentec, Cheonan, Korea) by a single surgeon at a single tertiary institution from September 2011 to August 2020, where 92 hips were treated. Thirty-nine patients were followed up for less than one year. Excluding those patients, the mean follow-up duration was 3.0 years (range 1–8 years). The patients’ deaths were confirmed through data from the Ministry of Interior and Safety. Clinical outcomes were assessed using a modified Harris hip score (mHHS), and radiologic outcomes, such as fixation and subsidence, were assessed by surgeons who did not participate in the surgery. @*Results@#mHHS improved from 45 to 79 points at the latest follow-up, and thigh pain was not observed in 53 patients who were followed up for more than one year. Notching of the stem was not noted. The average subsidence was approximately 1 mm in postoperative one year.Three peri-prosthetic fractures (PPF), one deep prosthetic infection, and one superficial wound infection were observed. Stem loosening occurred in one of these PPF cases, and stem revision surgery was done. All complications occurred within one year postoperatively. The one- and five-year mortality were 21.1% and 50.0%, respectively. @*Conclusion@#The short-term and mid-term results of the cementless hip arthroplasty using long double-tapered rectangular stem appeared encouraging and could be a viable option in osteoporotic proximal femoral fractures or reoperation cases. However, most complications occurred within one postoperative year, and the one-year mortality was relatively high. A long-term follow-up would be necessary with a larger cohort to evaluate its longevity.

5.
Clinics in Orthopedic Surgery ; : 21-27, 2022.
Article in English | WPRIM | ID: wpr-914111

ABSTRACT

Background@#Most isolated greater trochanter (IGT) fractures are treated conservatively. However, some require surgical fixation although indications for surgery have not yet been established. Many surgeons perform surgical fixation when the intertrochanteric extension crosses the midline on magnetic resonance (MR) images. Nevertheless, for mechanical strength, cortical bone integrity is more important than that of intramedullary cancellous trabeculae. We retrospectively evaluated the clinical usefulness of multiplanar reformation computed tomography (MPR CT) in determining treatment strategies for IGT fractures. @*Methods@#We evaluated 99 cases of suspected IGT fractures between October 2004 and December 2019. They were 66 women and 33 men with a mean age of 77 years. The mean follow-up period was 34 months. Most patients were evaluated with plain radiographs, followed by additional imaging study via MPR CT in 65 cases, magnetic resonance imaging (MRI) in 5 cases, and both in 17 cases. Typically, fractures were fixed surgically when a cortical breakage was detected in the intertrochanteric area on MPR CT, while fractures without evidence of cortical breakage on MPR CT were treated conservatively. @*Results@#In 13 out of 82 cases evaluated by MPR CT, incomplete cortical breakage in the intertrochanteric area was detected, of which 10 were treated surgically. The remaining 3 cases were treated conservatively due to patient’s refusal, poor medical condition, and failure to detect breakage. Of 69 cases without cortical breakage, 61 cases were successfully treated conservatively.Among the 17 cases evaluated by both MPR CT and MRI, cortical breakage was detected in 3, of which the intertrochanteric extension crossed the midline on the MR image only in 1 case. Of the remaining 14 cases without breakage, the intertrochanteric extension crossed the midline in 5. Among these 5 cases, 3 were treated conservatively. @*Conclusions@#The results suggest that MPR CT is a useful imaging modality for further evaluation of IGT fractures. It was especially valuable in evaluating cortical bone integrity, which may be more critical for fracture stability.

6.
Clinics in Orthopedic Surgery ; : 28-34, 2022.
Article in English | WPRIM | ID: wpr-914110

ABSTRACT

Background@#The Bencox M stem is a mid-short type 1 stem with additional unique design features. It has a reduced stem length and a lateral shoulder to facilitate minimally invasive surgery, as well as an angular lateral shoulder and a trapezoidal neck to minimize stem-liner impingement. There have been many mid-term reports on type 1 stems, but no results have been reported so far on this novel design type 1 femoral stem. This study presents the clinical and radiological outcomes of total hip arthroplasty performed with the M stem after a minimum 5-year follow-up. @*Methods@#From July 2014 to February 2015, 125 primary total hip arthroplasties using the M cementless femoral stem were performed on 112 patients in our hospital. Among them, 94 patients (106 hips) were eligible for the study and were followed up for more than 5 years. Our primary outcome was clinical results, which were evaluated by the Harris Hip Score (HHS), thigh pain, noise, and other complications. Secondary outcome was radiological outcomes. Seventy-seven hips were evaluated radiologically with attention to implant fixation, migration, loosening of component, degree of stress shielding, radiolucent lines, focal osteolysis, heterotopic ossification, and the evidence of impingement between the stem and liner. @*Results@#The average HHS improved from 54.6 points (range, 24–67 points) to 96.8 points (range, 91–100 points) at the latest follow-up. Three hips (2.8%) had intermittent thigh pain, which was tolerable without medication. Five hips (4.7%) had ceramicrelated noise. There were no other complications such as infection, nerve injury, dislocation, or revision. All implants showed radiographic evidence of stable fixation by bone ingrowth without migration. Fifty-seven hips (74%) showed mild femoral stress shielding. Distal cortical hypertrophy was detected in 7 hips (9%), and heterotopic ossification was observed in 17 hips (22%). No implant demonstrated focal osteolysis and notching of the femoral neck or shoulder on radiographs. @*Conclusions@#The minimum 5-year results of total hip arthroplasty performed with the M cementless femoral stem were encouraging clinically and radiologically. A long-term follow-up will be necessary to evaluate its longevity.

7.
Clinics in Orthopedic Surgery ; : 328-334, 2022.
Article in English | WPRIM | ID: wpr-937388

ABSTRACT

Background@#Incomplete fractures are assumed to occur in the intertrochanteric area as fractures at other sites, but reports of incomplete intertrochanteric fractures (IIFs) are rare. In 1999, Schultz et al. defined isolated greater trochanter fractures (GTFs) as IIFs when intertrochanteric extension is observed on magnetic resonance (MR) images. On multiplanar reformation computed tomography (MPR CT) images acquired for further study of apparently isolated GTFs, we noted incomplete cortical breakage in the intertrochanteric area. We then found that the fracture line was incomplete on plain radiographs in some intertrochanteric fractures. We evaluated IIFs and apparently isolated GTFs using MPR CT and analyzed the fracture patterns of IIFs that were confirmed using MPR CT. @*Methods@#Between February 2006 and June 2019, 36 cases of IIF were detected using MPR CT in 36 patients. They were 17 women and 19 men with a mean age of 74.7 years (range, 26–94 years). Plain radiographs and MPR CT images were evaluated by two experienced orthopedic surgeons. In addition, MR imaging was performed in 5 cases. @*Results@#Plain radiographs showed no evidence of fracture in 2 cases, isolated GTF in 7 cases, and IIF in 27 cases. In all cases, incomplete cortical breakage in the intertrochanteric area was confirmed on MPR CT images. Cortical breakage was located in the anterior portion of the intertrochanteric area, whereas the posterior portion remained intact in all cases. The detection rate of cortical breakage was higher on coronal or sagittal images than that on axial images. On MR images of 5 cases, intertrochanteric extensions were found in the medullary space. All extensions originated in the greater trochanter area and extended anteriorly in the axial plane and inferomedially in the coronal plane. On the T1-weighted mid-coronal image, the extension reached or passed the midline in 3 cases, and cortical breakage was detected in only 2 cases. @*Conclusions@#In all cases of IIF, cortical breakage was detected in the anterior portion of the proximal femur, leaving the posterior cortex intact. This finding is notably different from that of intertrochanteric extension (from posterior to anterior) detected on MR images of isolated GTFs.

8.
Clinics in Orthopedic Surgery ; : 184-190, 2022.
Article in English | WPRIM | ID: wpr-924877

ABSTRACT

Background@#The current trend of using short femoral stems in total hip arthroplasty (THA) is associated with angular deviation of the femoral stem towards the native femoral axis. The purpose of this study was to compare the difference in stem tilt angle between two different stems with a similar design except for the stem length. @*Methods@#This is a retrospective review of 66 patients who underwent primary THA between April 2012 and May 2016, using a trans-gluteal direct lateral approach by a single surgeon. We evaluated the femoral stem tilt angle in both the coronal and sagittal planes and performed multivariate logistic regression analysis to evaluate possible risk factors. We also simulated the range of motion (ROM) of the hip joint using three-dimensional computer-aided design software (SolidWorks, 2016) to examine the clinical significance of femoral stem tilt. @*Results@#The mean coronal tilt angle was 1.8° ± 1.0° in the conventional stem group and 1.6° ± 1.1° in the short stem group, showing no statistically significant difference between the groups (p = 0.570). However, the mean sagittal tilt angle was 4.0° ± 2.0° in the conventional stem group and 7.8° ± 2.0° in the short stem group (p < 0.001). The stem type and stem length had a linear correlation with the sagittal tilt angle (p < 0.001) in multivariate regression analysis. A simulated hip ROM demonstrated a 3.8° decrease in extension in proportion to a 3.8° increase in the mean sagittal stem tilt angle of the short femoral stem. @*Conclusions@#Anterior femoral stem tilting in the sagittal plane was prominent when the shorter stem was used, and anterior tilting was responsible for decreased ROM in hip extension.

9.
Hip & Pelvis ; : 40-44, 2021.
Article in English | WPRIM | ID: wpr-914515

ABSTRACT

There have been some reports of gross trunnion failure (GTF) in total hip arthroplasty. Here, we report a case of GTF 19 years after bipolar hemiarthroplasty using a 28-mm head with a 14/16 taper bore. Compared to other GTF reports, the current case had some unusual aspects: bipolar hemiarthroplasty, 28-mm head, relatively lateonset, and no apparent findings of metallosis though a severe one was evident. A Computed tomography scout view provided valuable information in evaluating polyethylene, metal head, and neck inside the bipolar cup. The current report suggests a need for concerned regarding short trunnion length which may be associated with GTF.

10.
Clinics in Orthopedic Surgery ; : 37-46, 2021.
Article in English | WPRIM | ID: wpr-874511

ABSTRACT

Background@#Outcomes of traditional treatment for osteonecrosis of the femoral head (ONFH) are not always satisfactory. Hence, cell-supplementation therapy has been attempted to facilitate necrotic-tissue regeneration. Adipose-derived mesenchymal stem cell (ADMSC) transplantation is potentially advantageous over bone marrow-derived MSC implantation, but its outcomes for ONFH remain unclear. The aim of this study was to determine 2-year radiological and clinical outcomes of culture-expanded autologous ADMSC implantation for ONFH. @*Methods@#Eighteen hips with necrotic lesions involving ≥ 30% of the femoral head were included. ADMSCs were harvested by liposuction and culture expanded for 3 passages over 3 weeks. With a 6-mm single drilling, ADMSCs were implanted into the necrotic zone. All patients underwent magnetic resonance imaging (MRI), single-photon emission computed tomography/computed tomography (SPECT/CT) at screening and 6 months, 12 months, and 24 months postoperatively. The primary outcome was the change in the size of necrotic area on MRI. Secondary outcomes were changes in clinical scores and radioisotope uptake on SPECT/CT. Conversion total hip arthroplasty (THA) was defined as the endpoint. @*Results@#Preoperatively, the necrotic lesion extent was 63.0% (38.4%–96.7%) of the femoral head. The mean Harris hip score was 89.2, the University of California at Los Angeles (UCLA) score was 5.6, and Western Ontario and McMaster Universities Arthritis index (WOMAC) was 79.4. Three patients underwent THA and 1 patient died in an accident. Finally, 11 patients (14 hips) were available for ≥ 2-year follow-up. At the last follow-up, no surgery-related complications occurred, and 14 of 17 hips (82%) were able to perform daily activities without THA requirement. There was no significant decrease in lesion size between any 2 intervals on MRI.However, widening of high signal intensity bands on T2-weighted images inside the necrotic lesion was observed in 9 of 14 hips (64%); 11 of 14 hips (79%) showed increased vascularity on SPECT/CT at 2 years postoperatively. No significant differences were observed between preoperative and 24-month mean Harris hip score (89.2 vs. 88.6), WOMAC (79.4 vs. 75.7), and UCLA score (5.6 vs. 6.2). @*Conclusions@#Our outcomes suggest that culture-expanded ADMSC implantation is a viable option for ONFH treatment without adverse events.

11.
Clinics in Orthopedic Surgery ; : 435-441, 2020.
Article in English | WPRIM | ID: wpr-831971

ABSTRACT

Background@#Hereditary multiple exostoses (HME) is an autosomal dominant disorder. The lesion in the proximal femoral metaphysis can bring about hip dysplasia and subsequent degenerative arthritis. Due to its rare prevalence, there have been a few case reports of total hip arthroplasty (THA) for osteoarthritis secondary to HME. The aim of this study was to report mid- to long-term outcomes of THA in HME patients and discuss special considerations that should be taken into account during surgery. @*Methods@#We retrospectively evaluated the clinical and radiological results of THA for osteoarthritis secondary to HME in 11 hips of 9 patients after a minimum follow-up of 5 years (mean, 9.9 years). There were 3 men (3 hips) and 6 women (8 hips), with a mean age of 53.6 years (range, 46.8–58 years) at the index surgery in this study. Harris hip score (HHS) was used for clinical outcome assessment, and radiologically, implant stability, radiolucent lines, liner wear, and any sign of osteolysis or implant loosening were evaluated. Postoperative complications including infection, deep vein thrombosis, and dislocations were also investigated. @*Results@#Cemented stems and cementless cups with the conventional polyethylene liner were used in bilateral hips of a single patient. In the other cases, cementless implants were used with ceramic-on-ceramic bearings. The mean HHS improved from 34.8 preoperatively to 92.5 postoperatively. Polyethylene liner wear and osteolysis were observed in 1 patient with cemented stems. Radiolucent lines were observed in 2 different cases. However, the femoral stems remained stable. There were no surgery-related complications except heterotopic ossification during follow-up. @*Conclusions@#Despite the several surgical considerations, the mid- to long-term clinical and radiological outcomes of THA in HME patients were satisfactory. The abnormal, wide mediolateral diameter of the proximal metaphysis should be considered in selecting and inserting the stem with adequate anteversion. Leg length discrepancy was also common, so teleradiographs should be obtained before surgery. Intraoperative leg length evaluation might be difficult due to the morphologic changes in the proximal femur after mass excision and individual bone length differences.

12.
Hip & Pelvis ; : 156-160, 2020.
Article in English | WPRIM | ID: wpr-898541

ABSTRACT

Mechanisms of ceramic liner fractures have not yet been fully elucidated. Impingement between a stem and ceramic liner is a proposed cause of ceramic liner fractures. We experienced a case of ceramic liner fracture caused by direct impingement between the stem shoulder and the ceramic liner. This type of impingement, unlike impingements with a stem neck, has not been previously reported. While we assume that certain characteristics of the stem contributed to the impingement, we report this case to note that caution may be needed when using certain stem designs.

13.
Hip & Pelvis ; : 156-160, 2020.
Article in English | WPRIM | ID: wpr-890837

ABSTRACT

Mechanisms of ceramic liner fractures have not yet been fully elucidated. Impingement between a stem and ceramic liner is a proposed cause of ceramic liner fractures. We experienced a case of ceramic liner fracture caused by direct impingement between the stem shoulder and the ceramic liner. This type of impingement, unlike impingements with a stem neck, has not been previously reported. While we assume that certain characteristics of the stem contributed to the impingement, we report this case to note that caution may be needed when using certain stem designs.

14.
Clinics in Orthopedic Surgery ; : 270-274, 2019.
Article in English | WPRIM | ID: wpr-763590

ABSTRACT

BACKGROUND: The isolated liner and head exchange procedure has been an established treatment method for polyethylene wear and osteolysis when the acetabular component remains well fixed. In this study, the mid-term results of this procedure were evaluated retrospectively. METHODS: Among the consecutive patients operated on from September 1995, two patients (three hips) were excluded because of inadequate follow-up, and the results of remaining 34 patients (34 hips) were evaluated. There were 20 men and 14 women with a mean age of 49 years. A conventional polyethylene liner was used in 26 cases and a highly cross-linked polyethylene liner was used in eight cases. In three cases, the liner was cemented in a metal shell because a compatible liner could not be used. RESULTS: After a follow-up of 5 to 20.2 years, re-revision surgery was necessary in 10 cases (29.4%): in eight for wear and osteolysis at 55 to 101 months after liner exchange and in two for acetabular loosening at 1 and 1.5 years after liner exchange. Re-revision surgery included all component revision (four cases), cup revision (four cases), and liner exchange (two cases). In all re-revision cases, a conventional polyethylene liner was used initially. There was no failure in the cases in which a highly cross-linked polyethylene liner was used. CONCLUSIONS: The results of this study suggest that isolated acetabular liner exchange is a reasonable option for wear and osteolysis when the metal shell is well fixed. More promising long-term results are expected with the use of highly cross-linked polyethylene liners.


Subject(s)
Female , Humans , Male , Acetabulum , Bone Screws , Follow-Up Studies , Fracture Fixation , Head , Humerus , Methods , Osteolysis , Polyethylene , Retrospective Studies
15.
Clinics in Orthopedic Surgery ; : 361-368, 2019.
Article in English | WPRIM | ID: wpr-763577

ABSTRACT

BACKGROUND: Adequate bone formation around titanium alloy implants is integral to successful implantation surgery. Stem cell-coated implants may accelerate peri-implant bone formation. This study investigates the effect of platelet-rich plasma (PRP) pretreatment on a titanium-alloy surface in terms of proliferation and osteogenic differentiation of human adipose-derived stem cells (hADSCs). METHODS: Allogenic leukocyte-depleted PRP was obtained from blood supernatants. The hADSCs were isolated from thigh subcutaneous fat tissue. Grit-blasted titanium plugs were used in two different groups. In one group, 200 µL of PRP was added to the grit-blasted titanium plugs. The hADSCs were seeded in two groups: grit-blasted titanium plugs with or without PRP. The number of hADSCs was measured after 4 hours, 3 days, and 7 days of culture using Cell Counting Kit-8. Osteogenesis of hADSCs was measured by using an alkaline phosphatase activity assay on days 7 and 14, and a calcium assay on days 14 and 21. Osteogenic gene expression was measured by using reverse transcription polymerase chain reaction analysis of alkaline phosphatase, osteocalcin, and type I collagen mRNA. The microscopic morphology of grit-blasted titanium plugs with or without PRP was examined with a field-emission scanning electron microscope using a JSM-7401F apparatus on days 1 and 7. RESULTS: Proliferation and osteogenic differentiation of hADSCs were found to be significantly higher on the grit-blasted titanium alloy preprocessed with PRP than the same alloy without pretreatment. Furthermore, a structural fibrillar mesh developed compactly on the grit-blasted titanium alloy with the PRP pretreatment. CONCLUSIONS: Our results demonstrate that a hADSC-based approach can be used for tissue-engineered peri-implant bone formation and that PRP pretreatment on the grit-blasted titanium alloy can improve proliferation and osteogenic differentiation of hADSCs.


Subject(s)
Humans , Alkaline Phosphatase , Alloys , Calcium , Cell Count , Collagen Type I , Gene Expression , Osteocalcin , Osteogenesis , Platelet-Rich Plasma , Polymerase Chain Reaction , Reverse Transcription , RNA, Messenger , Stem Cells , Subcutaneous Fat , Thigh , Titanium
16.
Hip & Pelvis ; : 162-167, 2018.
Article in English | WPRIM | ID: wpr-740431

ABSTRACT

PURPOSE: This study presents the clinical and radiological outcomes of cementless total hip arthroplasty using the COREN hip system after a minimum duration of follow-up of 5 years. MATERIALS AND METHODS: We evaluated the results of a consecutive series of the first 200 primary total hip arthroplasties that had been performed in our hospital in 169 patients between February 2007 and April 2011. Six patients (6 hips) had died within 5 years, and 12 patients (13 hips) had been lost to follow-up, leaving a total of 151 patients (181 hips) available for the study. All patients were evaluated clinically and radiologically with special attention to thigh pain, implant fixation, radiolucent line and osteolysis around implants. RESULTS: The mean Harris hip score improved from 59.4 preoperatively to 97.2 postoperatively. No patient complained of thigh pain. All implants demonstrated radiographic evidence of stable fixation by bone ingrowth without any change in position. No implant was loose radiographically or was revised. Eleven hips (7.7%) had a radiolucent line around the femoral stem. Focal osteolytic area was detected in 3 cases (2.1%). An osteolytic lesion was stabilized in 1 case and further observation was needed in 2 cases in which the lesions were detected several years after surgery. Stress shielding was observed in 80.3% of cases (first degree, 35.9%; second degree, 44.4%); there were no cases of third or fourth degree stress shielding. One case was complicated by bacterial infection and repeated dislocation. CONCLUSION: Mid-term results of total hip arthroplasty using the COREN hip system are very encouraging clinically and radiologically.


Subject(s)
Humans , Arthroplasty , Arthroplasty, Replacement, Hip , Bacterial Infections , Joint Dislocations , Follow-Up Studies , Hip , Lost to Follow-Up , Osteolysis , Thigh
17.
Clinics in Orthopedic Surgery ; : 20-25, 2018.
Article in English | WPRIM | ID: wpr-713672

ABSTRACT

BACKGROUND: This retrospective study was performed to determine whether postoperative intravenous ferric carboxymaltose reduces transfusion amounts without influencing clinical outcomes in patients that have undergone hip surgery. METHODS: Between May 2014 and April 2016, the authors adopted a new perioperative blood management protocol involving the administration of intravenous ferric carboxymaltose after hip surgeries. One-to-one matching between the 150 patients treated during this period with 150 patients treated before initiation of the new protocol was performed by propensity scoring for age, sex, diagnosis, and type of hip surgery. Hematologic results and clinical outcomes in these two groups were compared. RESULTS: Average amounts of perioperative blood loss were not different in the two groups. Ninety-two patients (61%) were transfused in the control group and 70 patients (47%) were transfused in the intravenous ferric carboxymaltose group. The average number of transfused blood units was significantly lower in the intravenous ferric carboxymaltose group (1.7 ± 2.7 units vs. 1.0 ± 1.2 units, p = 0.002). At 6 weeks after surgery, the average hemoglobin concentration recovered to baseline in both groups, but the amount of recovered hemoglobin concentration at 6 weeks was significantly greater in the intravenous ferric carboxymaltose group than in the control group. Clinical outcomes including incidences of postsurgical complications were similar between the two groups. CONCLUSIONS: This study suggests that postoperative intravenous ferric carboxymaltose injection is associated with reduced transfusion amounts and that intravenous ferric carboxymaltose does not influence clinical outcomes after hip surgery.


Subject(s)
Humans , Anemia , Blood Transfusion , Diagnosis , Hip , Incidence , Orthopedics , Postoperative Hemorrhage , Retrospective Studies
18.
Clinics in Orthopedic Surgery ; : 19-28, 2017.
Article in English | WPRIM | ID: wpr-71105

ABSTRACT

BACKGROUND: Total hip arthroplasty with subtrochanteric shortening osteotomy is widely performed for high hip dislocation. However, suboptimal leg length discrepancy correction and nonunion of the osteotomy site remain concerns. Although total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy was introduced, cemented implants have been more commonly used than contemporary cementless implants in this procedure. We evaluated the long-term results of cementless total hip arthroplasty with trochanteric osteotomy without subtrochanteric osteotomy for high hip dislocation. METHODS: From 1990 to 2002, 27 cementless total hip arthroplasties using trochanteric osteotomy without subtrochanteric osteotomy were performed in 26 patients with Crowe III or IV high hip dislocation and a mean age of 36.4 ± 12.9 years. Seven ceramic-on-ceramic, 8 ceramic-on-polyethylene, 10 metal-on-polyethylene, and 2 metal-on-metal bearings were inserted. Mean follow-up was 15.1 ± 3.7 years. We retrospectively reviewed medical records and radiographic data and evaluated the clinical and radiological results including the Harris hip score, implant survival, correction of leg length discrepancy, and occurrence of complications. RESULTS: The mean Harris hip score and leg length discrepancy improved significantly from 73.3 to 94.9 points and from 4.3 cm to 1.0 cm, respectively. With revision for loosening set as the end point, implant survival rates at 10 and 15 years postoperatively were 96.0% and 90.9% for stems and 74.1% and 52.3% for cups. In 8 of 10 hips with the metal-on-polyethylene bearing and 4 of 8 hips with the ceramic-on-polyethylene bearing, revision surgery was performed for aseptic loosening. However, no revision was performed in hips with the ceramic-on-ceramic bearing or the metal-on-metal bearing. Implant survival was significantly different by the type of bearing surface. Two permanent neurologic complications occurred in patients with a limb lengthening over 3.5 cm. CONCLUSIONS: With proper selection of the bearing surface coupled with adjustment of lengthening, cementless total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy might be a favorable treatment option for high hip dislocation.


Subject(s)
Humans , Arthroplasty , Arthroplasty, Replacement, Hip , Crows , Joint Dislocations , Extremities , Femur , Follow-Up Studies , Hip Dislocation , Hip Dislocation, Congenital , Hip , Leg , Leg Length Inequality , Medical Records , Osteotomy , Retrospective Studies , Survival Rate
19.
Clinics in Orthopedic Surgery ; : 37-42, 2017.
Article in English | WPRIM | ID: wpr-71103

ABSTRACT

BACKGROUND: Venous thromboembolism (VTE) is a relatively common and potentially life threatening complication after major hip surgery. There are two main types of prophylaxis: chemical and mechanical. Chemical prophylaxis is very effective but causes bleeding complications in surgical wounds and remote organs. On the other hand, mechanical methods are free of hemorrhagic complications but are less effective. We hypothesized that mechanical prophylaxis is effective enough for Asians in whom VTE occurs less frequently. This study evaluated the effect of intermittent pneumatic compression (IPC) in the prevention of VTE after major hip surgery. METHODS: Incidences of symptomatic VTE after primary total hip arthroplasty with and without application of IPC were compared. A total of 379 patients were included in the final analysis. The IPC group included 233 patients (106 men and 127 women) with a mean age of 54 years. The control group included 146 patients (80 men and 66 women) with a mean age of 53 years. All patients took low-dose aspirin for 6 weeks after surgery. IPC was applied to both legs just after surgery and maintained all day until discharge. When a symptom or a sign suspicious of VTE, such as swelling or redness of the foot and ankle, Homans' sign, and dyspnea was detected, computed tomography (CT) angiogram or duplex ultrasonogram was performed. RESULTS: Until 3 months after surgery, symptomatic VTE occurred in three patients in the IPC group and in 6 patients in the control group. The incidence of VTE was much lower in the IPC group (1.3%) than in the control group (4.1%), but the difference was not statistically significant. Complications associated with the application of IPC were not detected in any patient. Patients affected by VTE were older and hospitalized longer than the unaffected patients. CONCLUSIONS: The results of this study suggest that IPC might be an effective and safe method for the prevention of postoperative VTE.


Subject(s)
Humans , Male , Ankle , Arthroplasty, Replacement, Hip , Asian People , Aspirin , Dyspnea , Foot , Hand , Hemorrhage , Hip , Incidence , Leg , Methods , Ultrasonography , Venous Thromboembolism , Wounds and Injuries
20.
Journal of Korean Medical Science ; : 80-88, 2016.
Article in English | WPRIM | ID: wpr-218586

ABSTRACT

The aim of this study was to examine the incidence and trends of clinically relevant venous thromboembolism (VTE) including deep vein thrombosis (DVT) and pulmonary embolism (PE) after hip and knee replacement arthroplasty (HKRA) in Korea. Between January 1 and December 31, 2010, 22,127 hip replacement arthroplasty (HRA) patients and 52,882 knee replacement arthroplasty (KRA) patients were enrolled in the analysis using the administrative claims database of the Health Insurance Review and Assessment Service (HIRA). All available parameters including procedure history and clinically relevant VTE during the 90 days after HKRA were identified based on diagnostic and electronic data interchange (EDI) codes. The overall incidence of VTE, DVT, and PE during the 90 days was 3.9% (n=853), 2.7% (n=597), and 1.5% (n=327) after HRA, while the incidence was 3.8% (n=1,990), 3.2% (n=1,699), and 0.7% (n=355) after KRA. The incidence of VTE after HKRA was significantly higher in patients who had previous VTE history (odds ratio [OR], 10.8 after HRA, OR, 8.5 after KRA), chronic heart failure (2.1, 1.3), arrhythmia (1.8, 1.7), and atrial fibrillation (3.4, 2.1) than in patients who did not. The VTE incidence in patients with chemoprophylaxis was higher than that in patients without chemoprophylaxis. The incidence of VTEs revealed in this retrospective review was not low compared with the results of the studies targeting other Asian or Caucasian populations. It may warrant routine prevention including employment of chemoprophylaxis. However, the limitation of the reviewed data mandates large scale prospective investigation to affirm this observation.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Databases, Factual , Incidence , National Health Programs , Odds Ratio , Republic of Korea/epidemiology , Retrospective Studies , Risk Factors , Venous Thromboembolism/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL